51.326 - Airflo 300 Filter/Regulator+Lubricator 3/8 Auto

229.99$

Description

Technical specifications and certifications

• Port Size: 3/8 (F) NPT
• Maximum Airflow at 100 PSI: 60 SCFM
• Maximum Working Pressure: 150 PSI
• Pressure Range: Standard: 5-125 PSI
• Options: 5-30 PSI • 5-60 PSI
• Working Temperature: 5 to 60 °C
• Filtration: 5 microns
• Drain: Automatic drain
• Bowl Capacity: Filter: 20 ml, Lubricator: 50 ml
• Pressure Gauge Port Size: 1/8 (F) NPT

Material(s):
• Body Material(s): Die-cast aluminum
• Bowl Type: Polycarbonate with steel guard
• Bowl Guard: Steel
• Regulation Type: Relieving
• Filter Element: Polyethylene, 5 microns
• Deflector & Spinner: ABS
• O-Rings & Seals: EPDM rubber
• Regulator Cap: Reinforced nylon
• Regulator Adjusting Knob: Reinforced nylon
• Diaphragm: EPDM rubber
• Poppet Valve: Brass and rubber
• Regulator Spring: Stainless steel
• Lubricator Sight Gauge: Polycarbonate
• Fill Plug: ABS
• Retainer: ABS
• Lubricator Adjusting Knob: ABS
• Check Flap: Polyurethane Specifications

Features and benefits

• Compact design with space-saving integrated filter/regulator
• Accurate pressure control with little drift
• Removable locking push-pull adjusting knob
• Standard semi-automatic drain requires a simple tug of the ring to drain
• Lubrication proportioned to airflow
• Pressure gauge, piping adapters, and mounting bracket included

Operation and installation

WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application

WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools require different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application

WHERE TO INSTALL A LUBRICATOR
Install as close to the tool as possible, within 5 meters or 30 meters for micro-fog type lubricators
Always install downstream of a filter and a regulator
Ensure that the lubricator is easily accessible for filling pneumatic tool oil
Always install with the arrows pointing to the tool or application

Additional information

Type

Airflo 300